Centro de Suporte

Baixe planilhas, resumos técnicos, guias de instalação e muito mais.



Filtrar por
¸é±ð²µ¾±Ã£´Ç
Sua seleção (3)
Todos documentos
(3)
IQ Gateway software release notes (8.2.4401)
January 3, 2025

IQ Gateway software version 8.2.4401 supports backward compatibility of IQ8 Series Microinverters with existing IQ7 Series Microinverter sites in the countries mentioned below.

  • Countries: The United States, Puerto Rico, Canada, Mexico, Bermuda, Brazil, and the Philippines

    #FeatureDescription
    1Support for IQ7 and IQ8 mixed systems

    Supports backward compatibility of IQ8 Series Microinverters in the existing IQ7 Series Microinverter systems on the same IQ Gateway only in the following configurations:

    • Grid-tied (without backup) Solar Only systems
    • Grid-tied (without backup) solar and storage systems with IQ Battery 5P
    • Grid-tied (without backup) solar and storage systems with IQ Battery 3T/10T

    NOTE: IQ7 Series Microinverters cannot be added to a site with existing IQ8 Series Microinverters on the same gateway. A mixed system of IQ7 and IQ8 will not support IQ8-specific PCS features and grid-forming capabilities.

  • Gateways supported:
     
    • Puerto Rico and the United States:
       
      • IQ Combiner 5/5C/4/4C/3/3C/3-ES/3C-ES and IQ Combiner 4/4C (IEEE 1547-2018 compliant)
      • IQ Gateway and IQ Gateway (IEEE 1547-2018 compliant)
    • Brazil and Philippines:
       
      • IQ Gateway M
      • IQ Gateway (only for Brazil)
    • Canada, Mexico, and Bermuda:
       
      • IQ Combiner 5/4 and IQ Combiner 4 (IEEE 1547-2018 compliant)
      • IQ Gateway and IQ Gateway (IEEE 1547-2018 compliant)
  • Microinverters supported:
     
    • Puerto Rico and the United States:
       
      • IQ8 Series (SKU - IQ8A-72-2-US, IQ8A-72-M-US, IQ8H-208-72-2- US, IQ8H-208-72-M-US, IQ8H-240-72-2-US, IQ8H-240-72-M-US, IQ8MC-72-M-US, IQ8AC-72-M-US, IQ8HC-72-M-US, IQ8M-72-2- US, IQ8M-72-M-US, IQ8P-72-2-US, IQ8PLUS-72-2-US, IQ8PLUS- 72-M-US, IQ8X-80-M-US)
      • IQ7 Series (all SKUs)
    • Canada, Mexico, and Bermuda:
       
      • IQ8 Series (SKU - IQ8A-72-2-US, IQ8A-72-M-US, IQ8H-208-72-2- US, IQ8H-208-72-M-US, IQ8H-240-72-2-US, IQ8H-240-72-M-US, IQ8MC-72-M-US, IQ8AC-72-M-US, IQ8HC-72-M-US, IQ8M-72-2- US, IQ8M-72-M-US, IQ8P-72-2-US, IQ8PLUS-72-2-US, IQ8PLUS- 72-M-US, IQ8X-80-M-US (only for Canada))
      • IQ7 Series (all SKUs)
    • Brazil:
       
      • IQ8 Series (SKU - IQ8P-72-2-BR)
      • IQ7 Series (IQ7AM and IQ7Plus)
    • Philippines:
       
      • IQ8 Series (SKU - IQ8P-72-2-US)
      • IQ7 Series (all SKUs)
  • Batteries supported:
     
    • Puerto Rico and the United States:
       
      • Third-generation IQ Batteries: IQ Battery 5P
      • Second-generation IQ Batteries: IQ Battery 3T/10T
      • First-generation IQ Batteries: IQ Battery 3/10
    • Canada, Mexico, and Bermuda:
       
      • Third-generation IQ Batteries: IQ Battery 5P
      • Second-generation IQ Batteries: IQ Battery 3T/10T
  • Supported system configurations:  
     
    • Puerto Rico and the United States:
       
      • Grid-tied (without backup) Solar Only systems with IQ8 Series Microinverters & IQ7 Series Microinverters (mixed) and IQ Combiner 5/5C or IQ Combiner 4/4C (IEEE 1547-2018 compliant) or IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IQ Gateway (IEEE 1547-2018 compliant) or IQ Gateway
      • Grid-tied (without backup) solar and storage systems with IQ8 Series & IQ7 Series Microinverters (mixed), IQ Battery 5P, and IQ Combiner 5/5C
      • Grid-tied (without backup) solar and storage systems with IQ8 Series & IQ7 Series Microinverters (mixed), IQ Battery 5P, IQ Combiner 4/4C (IEEE 1547-2018 compliant) or IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IQ Gateway (IEEE 1547-2018 compliant) or IQ Gateway, and Communications Kit 2
      • Grid-tied (without backup) solar and storage systems with IQ8 Series & IQ7 Series Microinverters (Mixed), IQ Battery 3T/10T, IQ Combiner 5/5C or IQ Combiner 4/4C (IEEE 1547-2018 compliant) or IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IQ Gateway (IEEE 1547-2018 compliant) or IQ Gateway, and Communications Kit 1
    • Canada, Mexico and Bermuda:
       
      • Grid-tied (without backup) Solar Only systems with IQ8 Series & IQ7 Series Microinverters (mixed), and IQ Combiner 5 or IQ Gateway (IEEE 1547-2018 compliant) or IQ Gateway
    • Brazil and Philippines:
       
      • Grid-tied (without backup) Solar Only systems with IQ8P and IQ7 Series Microinverters (mixed), and IQ Gateway M
      • Grid-tied (without backup) Solar Only systems with IQ8P and IQ7 Series Microinverters (mixed), or IQ8P Microinverters and IQ Gateway (only for Brazil)

This release is being deployed via the ţţËã·¨ Installer App to systems with IQ8 Series and IQ7 Series (mixed) Microinverters.

IQ Gateway software release notes (8.2.4378)
November 1, 2024

IQ Gateway software version 8.2.4378 improves the performance of the ţţËã·¨ System for the countries listed below. It also supports busbar overload control and ţţËã·¨ electric vehicle supply equipment (EVSE) dynamic load balancing Power Control System (PCS) features for the United States and Puerto Rico. 

  • Countries: United States, Bermuda, Brazil, Canada, Mexico, the Philippines, and Puerto Rico
  • Release notes:

    #FeatureDescription
    1Introduces the Power Control (PCS) main panel upgrade avoidance (MPUA) with busbar overload control feature for the United States and Puerto Rico

    Supports MPUA with busbar overload control for Solar Only systems with IQ8 Series Microinverters and grid-tied or grid-forming Solar Plus Batteries systems with IQ8 Series Microinverters and IQ Battery 5P.


    Power Control with busbar overload control accelerates the system payback period by enabling maximum renewable energy generation. This feature enables the safe installation of larger solar and battery systems while maximizing power through a larger backfeed—without costly upgrades to the main panel.

    2Introduces the ţţËã·¨ IQ EV Charger Power Control System (PCS) feature for the United States and Puerto Rico

    The dynamic load balancing PCS feature in the ţţËã·¨ IQ EV Charger is designed to monitor the total energy consumption of your home. This feature is crucial as it ensures that the charger adjusts its charging current based on the home’s overall power usage. This is supported for all models of the IQ EV Charger (IQ-EVSE-NA, 40 A, 50 A, 60 A, and 80 A) installed with an IQ Gateway or IQ Combiner.


    This enables the installation of a more powerful IQ EV Charger by avoiding main breaker trips when home loads are extremely high—saving installation costs that would otherwise be incurred by main breaker/service upgrades.

    3Supports full Off-Grid operation
    • Supports microinverter phase association during Off-Grid operation and keeps communication healthy with the gateway.
    • Provides an option to configure the system to operate Off-Grid via the ţţËã·¨ Installer App or ţţËã·¨ Installer Portal using a gateway REST API.
       
    4Improves IQ Battery 5P battery management unit (BMU) behavior
    • Improves State-of-Charge (SoC) calibrations under lower and higher SoC conditions.
    • Resolves an issue with battery power conversion units (PCU) pre-charge, which helps recover the battery from extreme low SoC conditions.
    • Fixes an issue with a continuous battery software reset event when a software update is tried while the battery is in a very low SoC condition.
    • Correct an issue where the BMU reads the cell voltage incorrectly and becomes non-operational when the DC Switch is turned off and on.
    • Fixes an issue seen on sites with M Series Microinverters; a rare instance of SoC drop was observed due to manual SoC calibration done by the Battery Controller as part of compensating leakage current.
    • Corrects a sudden jump in the battery SoC value due to forced calibration of the SoC.
    • Addresses incorrect State-of-Health (SoH) calibration when the battery unit charges fully and then discharges more than 50% of its capacity
       
    5Faster battery charging for Off-Grid systems with IQ7 Series Microinverters

    This software release enables faster charging and more reliable state of charge (SoC) recovery for Off-Grid batteries connected to systems with IQ7 Series Microinverters. This improvement is achieved by changing the following parameters for IQ7 Series Microinverters:

    • Reduced entry service time: The entry service time is minimized to just 1 second.
    • Increased ramp rate: The ramp rate is boosted to 100% per second.

    These enhancements are activated only when an IQ System Controller is present and functioning normally. This ensures that the controller manages grid interconnection parameters in accordance with utility requirements, rather than relying solely on the photovoltaic (PV) microinverters.

    6Improves cloud reporting behavior
    • The ţţËã·¨ App sends homeowner notifications when there is a grid outage and the battery SoC is below 50%, 30%, or a very low SoC. These notifications will be sent until grid power is restored.
    • Increases the amount and frequency of data reported to the ţţËã·¨ Cloud when IQ Gateway connectivity is restored after loss of internet connection.
    • Fixes an issue where IQ Battery telemetry data gets missed, leading to spikes in graphs on the ţţËã·¨ Installer Portal.
    • Includes phase imbalance management (PIM) system settings in the configuration report.
    7Bug fixes and feature enhancements
    • Disables the PV breaker open detection in the IQ System Controller (version 1) since it is unnecessary for system controller versions that do not support IQ8 Microinverters.
    • Addresses meter spikes that are observed during software upgrades.
    • Resolves an issue with battery CPU memory access faults during software upgrades.
    • Corrects an issue where the IQ Batteries showed low DC voltages under fully charged conditions.
    • Fixes an issue where microinverters were down due to boot-diode failure.
    • Removes stale alarms caused by time synchronization issues between the gateway and the ţţËã·¨ App.
    • Enhances security features.
       
  • Gateways supported:
     
    •  United States and Puerto Rico:
       
      • IQ Combiner 5/5C/4/4C/3/3C/3-ES/3C-ES and IEEE 1547-2018 compliant IQ Combiner 4/4C
      • IQ Gateway and IEEE 1547-2018 compliant IQ Gateway
      • IQ Gateway Commercial and IQ Gateway Commercial 2
      • Envoy S Metered and Envoy S Standard for North America
    • Brazil and Philippines:
       
      • IQ Gateway M
      • IQ Gateway Commercial
      • IQ Gateway (only for Brazil)
    • Bermuda, Canada, and Mexico:
       
      • IQ Combiner 5/4, IEEE 1547-2018 compliant IQ Combiner 4
      • IQ Gateway, IEEE 1547-2018 compliant IQ Gateway
      • IQ Gateway Commercial, IQ Gateway Commercial 2 (Only for Canada and Mexico)
  • Microinverters supported:
     
    • United States and Puerto Rico:
       
      • IQ8 Series (SKU - IQ8A-72-2-US, IQ8A-72-M-US, IQ8H-208-72-2-US, IQ8H-208-72-M-US, IQ8H-240-72-2-US, IQ8H-240-72-M-US, IQ8MC-72-M-US, IQ8AC-72-M-US, IQ8HC-72-M-US, IQ8M-72-2-US, IQ8M-72-M-US, IQ8P-3P-72-E-US, IQ8H-3P-72-E-US, IQ8P-72-2-US, IQ8PLUS-72-2-US, IQ8PLUS-72-M-US, IQ8X-80-M-US)
      • IQ7 Series
      • IQ6 Series 
      • M Series
      • S Series
    • Bermuda, Canada, and Mexico:
       
      • IQ8 Series (SKU - IQ8A-72-2-US, IQ8A-72-M-US, IQ8H-208-72-2-US, IQ8H-208-72-M-US, IQ8H-240-72-2-US, IQ8H-240-72-M-US, IQ8MC-72-M-US, IQ8AC-72-M-US, IQ8HC-72-M-US, IQ8M-72-2-US, IQ8M-72-M-US, IQ8P-3P-72-E-US (only for Canada and Mexico), IQ8H-3P-72-E-US (only for Canada and Mexico), IQ8P-72-2-US, IQ8PLUS-72-2-US, IQ8PLUS-72-M-US, IQ8X-80-M-US (only for Canada))
      • IQ7 Series 
    • Brazil
       
      • IQ8 Series (SKU - IQ8P-72-2-BR)
      • IQ7AM
    • Philippines
       
      • IQ8 Series (SKU - IQ8P-72-2-US)
      • IQ7 Series
  • Batteries supported:
     
    • United States and Puerto Rico:
       
      • IQ Battery 5P, IQ Battery 3/3T/10/10T
    • Bermuda, Canada, and Mexico:
       
      • IQ Battery 5P, IQ Battery 3/3T/10/10T
  • System controllers supported:
     
    • United States and Puerto Rico:
       
      • IQ System Controller 3/3G/2, IQ System Controller
    • Bermuda, Canada, and Mexico:
       
      • IQ System Controller 3/3G/2
  • Supported system configurations:
     
    • The following configurations are supported in the United States and Puerto Rico:
       
      1. Grid-tied (without backup) Solar Only systems with M Series or S Series Microinverters and Envoy S Metered or Envoy S Standard for North America
      2. Grid-tied (without backup) Solar Only systems with IQ6 Series Microinverters and IQ Combiner 5/5C/4/4C/3/3C/3-ES/3C-ES or IQ Gateway
      3. Grid-tied (without backup) Solar Only systems with IQ7 Series Microinverters and IQ Combiner 5/5C or IEEE 1547-2018 compliant IQ Combiner 4/4C or IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway
      4. Grid-tied (without backup) Solar Only systems with IQ8 Series Microinverters and IQ Combiner 5/5C or IEEE 1547-2018 compliant IQ Combiner 4/4C or IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway
      5. Grid-tied (without backup) Solar Plus Batteries systems with IQ7 Series Microinverters, IQ Battery 5P, and IQ Combiner 5/5C
      6. Grid-tied (without backup) Solar Plus Batteries systems with IQ8 Series Microinverters, IQ Battery 5P, and IQ Combiner 5/5C
      7. Grid-tied (without backup) Solar Plus Batteries systems with IQ8 Series or IQ7 Series Microinverters and IQ Gateway Commercial
      8. Grid-tied (without backup) Solar Plus Batteries systems with IQ8 Series Commercial Microinverters (SKU- IQ8P-3P-72-E-US, IQ8H-3P-72-E-US) and IQ Gateway Commercial 2
      9. Grid-tied (without backup) Solar Plus Batteries systems with IQ7 Series Microinverters, IQ Battery 5P, IEEE 1547-2018 compliant 4/4C or IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway, and Communications Kit 2
      10. Grid-tied (without backup) Solar Plus Batteries systems with IQ8 Series Microinverters, IQ Battery 5P, IEEE 1547-2018 compliant IQ Combiner 4/4C or IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway, and Communications Kit 2
      11. Grid-tied (without backup) Solar Plus Batteries systems with IQ7 Series Microinverters, IQ Battery 3/3T/10/10T, IQ Combiner 5/5C or IEEE 1547-2018 compliant IQ Combiner 4/4C or IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway, and Communications Kit
      12. Grid-tied (without backup) Solar Plus Batteries systems with IQ8 Series Microinverters, IQ Battery 3/3T/10/10T, IQ Combiner 5/5C or IEEE 1547-2018 compliant IQ Combiner 4/4C or IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway, and Communications Kit
      13. Grid-tied (without backup) Solar Plus Batteries systems with M Series Microinverters, IQ Battery 5P, Envoy S Metered for North America, and Communications Kit 2
      14. Grid-tied (without backup) Solar Plus Batteries systems with M Series Microinverters, IQ Battery 3/3T/10/10T, Envoy S Metered for North America, and Communications Kit
      15. Sunlight Backup systems with IQ8 Series Microinverters, IQ System Controller 3/3G, and IQ Combiner 5/5C
      16. Sunlight Backup systems with IQ8 Series Microinverters, IQ System Controller 3/3G, IEEE 1547-2018 compliant IQ Combiner 4/4C or IQ Combiner 4/4C or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway, and Communications Kit 2
      17. Sunlight Backup systems with IQ8 Series Microinverters, IQ System Controller 2, IEEE 1547-2018 compliant IQ Combiner 4/4C or IQ Combiner 4/4C or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway, and Communications Kit
      18. Grid-forming (with backup) Solar Plus Batteries systems with IQ6 Series Microinverters, IQ Battery 5P, IQ System Controller 3/3G, and IQ Combiner 5/5C
      19. Grid-forming (with backup) Solar Plus Batteries systems with IQ6 Series Microinverters, IQ Battery 5P, IQ System Controller 3/3G, IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IQ Gateway, and Communications Kit 2
      20. Grid-forming (with backup) Solar Plus Batteries systems with IQ7 Series Microinverters, IQ Battery 5P, IQ System Controller 3/3G, and IQ Combiner 5/5C
      21. Grid-forming (with backup) Solar Plus Batteries systems with IQ8 Series Microinverters, IQ Battery 5P, IQ System Controller 3/3G, and IQ Combiner 5/5C
      22. Grid-forming (with backup) Solar Plus Batteries systems with IQ7 Series Microinverters, IQ Battery 5P, IQ System Controller 3/3G, IEEE 1547-2018 compliant IQ Combiner 4/4C or IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway, and Communications Kit 2
      23. Grid-forming (with backup) Solar Plus Batteries systems with IQ8 Series Microinverters, IQ Battery 5P, IQ System Controller 3/3G, IEEE 1547-2018 compliant IQ Combiner 4/4C or IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway, and Communications Kit 2
      24. Grid-forming (with backup) Solar Plus Batteries systems with M215 or M250 Microinverters, IQ Battery 5P, IQ System Controller 3/3G, Envoy S Metered for North America, and Communications Kit 2
      25. Grid-forming (with backup) Solar Plus Batteries systems with IQ6 Series Microinverters, IQ Battery 3/3T/10/10T, IQ System Controller 1/2, IQ Combiner 3/3C/3-ES/3C-ES/4/4C or IQ Gateway, and Communications Kit
      26. Grid-forming (with backup) Solar Plus Batteries systems with IQ7 Series Microinverters, IQ Battery 3/3T/10/10T, IQ System Controller 1/2, IEEE 1547-2018 compliant IQ Combiner 5/5C/4/4C or IQ Combiner 3/3C/3-ES/3C-ES/4/4C or IQ Gateway or IEEE 1547-2018 compliant IQ Gateway, and Communications Kit
      27. Grid-forming (with backup) Solar Plus Batteries systems with IQ8 Series Microinverters, IQ Battery 3/3T/10/10T, IQ System Controller 2, IEEE 1547-2018 compliant IQ Combiner 5/5C/4/4C or IQ Combiner 3/3C/3-ES/3C-ES/4/4C or IQ Gateway or IEEE 1547-2018 compliant IQ Gateway, and Communications Kit
      28. Grid-forming (with backup) Solar Plus Batteries systems with M215 or M250 Microinverters, IQ Battery 3/3T/10/10T, IQ System Controller 1/2, Envoy S Metered for North America, and Communications Kit
      29. Grid-forming (with backup) Battery Only systems with IQ Battery 5P, IQ System Controller 3/3G, and IQ Combiner 5/5C
      30. Grid-forming (with backup) Battery Only systems with IQ Battery 5P, IQ System Controller 3/3G, IEEE 1547-2018 compliant IQ Combiner 4/4C or IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway, and Communications Kit 2
      31. Grid-tied (without backup) Battery Only systems with IQ Battery 5 and IQ Combiner 5/5C or IQ Gateway with Communications Kit 2 or IEEE 1547-2018 compliant IQ Gateway with Communications Kit 2
    • Note: The following features are supported only in these specific configurations.
       
      • Load Control and Generator Support are supported in configurations 15 through 30.
      • Solar circuit control (PV shedding) is supported in configurations 15 through 28.
    • The following configurations are supported in Bermuda, Canada, and Mexico:
       
      1. Grid-tied (without backup) Solar Only systems with IQ7 Series Microinverters and IQ Combiner 5 or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway
      2. Grid-tied (without backup) Solar Only systems with IQ8 Series Microinverters and IQ Combiner 5 or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway
      3. Grid-forming (with backup) Solar Plus Batteries systems with IQ7 Series Microinverters, IQ Battery 5P, IQ System Controller 3/3G, and IQ Combiner 5 or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway and Communications Kit 2
      4. Grid-forming (with backup) Solar Plus Batteries systems with IQ8 Series Microinverters, IQ Battery 5P, IQ System Controller 3/3G, and IQ Combiner 5 or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway and Communications Kit 2
      5. Grid-forming (with backup) Solar Plus Batteries systems with IQ7 Series Microinverters, IQ Battery 3T/10T, IQ System Controller 2, and IQ Combiner 5 or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway, and Communications Kit 
      6. Grid-forming (with backup) Solar Plus Batteries systems with IQ8 Series Microinverters, IQ Battery 3T/10T, IQ System Controller 3/3G, and IQ Combiner 5 or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway, and Communications Kit
      7. Grid-tied (without backup) Solar Plus Batteries systems with IQ7 Series or IQ8 Series Microinverters (SKU- IQ8P-3P-72-E-US, IQ8H-3P-72-E-US, IQ8PLUS-72-2-US, IQ8PLUS-72-M-US), IQ Gateway Commercial (only for Canada and Mexico)
      8. Grid-tied (without backup) Solar Plus Batteries systems with IQ7 Series or IQ8 Series Microinverters (SKU- IQ8P-3P-72-E-US, IQ8H-3P-72-E-US, IQ8PLUS-72-2-US, IQ8PLUS-72-M-US) and IQ Gateway Commercial 2 (only for Canada)
    • The following configurations are supported in Brazil and the Philippines:
       
      • Grid-tied (without backup) Solar Only systems with IQ7 Series or IQ8P Microinverters and IQ Gateway M or IQ Gateway Commercial
      • Grid-tied (without backup) Solar Only systems with IQ7 Series or IQ8P Microinverters and IQ Gateway (Only for Brazil)
         

This release is being deployed to all IQ Gateway, IQ Combiner, Envoy S Metered, and Envoy S Standard devices stated above through remote software upgrades for existing systems. Note that this release is currently being deployed to sites connected to the internet via Wi-Fi or Ethernet. Sites connected to the internet via ţţËã·¨ Mobile Connect cellular modems will receive a different software version as a maintenance release at a later date.

 

IQ Gateway software release notes (7.6.336)
December 8, 2023

IQ Gateway software version 7.6.336 supports IQ7 Series and M Series Microinverters along with IQ Battery 3T/10T and AC Battery for Germany, Belgium, Austria, France, Netherlands, and Switzerland.

  • Gateways supported: IQ Gateway Metered
  • Countries:  Austria, Belgium, France, Germany, Netherlands, Switzerland
  • Microinverters supported: IQ7 Series, M Series, third-party string inverters
  • Batteries supported: IQ Battery 3T/10T, AC Battery
  • Supported system configurations:

    • Grid-tied solar and storage systems with IQ7 Series Microinverters, IQ Gateway Metered, and IQ Battery 3T/10T
    • Grid-tied solar and storage systems with compatible third-party string inverters, IQ Gateway Metered, and IQ Battery 3T/10T
    • Grid-tied solar and storage systems with M Series Microinverters, IQ Gateway Metered, and IQ Battery 3T/10T
    • Grid-tied solar and storage systems with IQ7 Series Microinverters, IQ Gateway Metered, and AC Battery
    • Grid-tied solar and storage systems with M Series Microinverters, IQ Gateway Metered, and AC Battery

    #

    FeatureDescription

    1

    Bug fixes
    • Fixes the issue of multiple USB unplugged events observed in the ţţËã·¨ Installer Portal.
    • Fixes the issue of microinverters, batteries, and other devices not reporting status by improving the Zigbee communication.
    • Fixes the issue of the Battery Management Unit (BMU) shutting down whenever the IQ battery is idle.
    • Fixes the issue of undesirable power consumption (tare loss) by the battery when in idle state.
    • Fixes the issue of IQ Battery maximum state-of-charge (SoC) being limited to 97% instead of 100%.
    • Fixes the issue of Phase Imbalance Management (PIM) getting enabled for single-phase systems.

     

    This release is being deployed via remote software upgrades for all systems.